Hospital Multi - parameter Portable Patient Monitor with ECG , RESP , NIBP
Descrition:
Portable Multiparameter Patient Monitor with ECG, RESP, NIBP, SpO2, TEMP, PR
12.1 inch TFT screen
Optional with thermal recorder, IBP, ETCO2
resolution ratio:800*600BMP
luminance:300-350
MEAS: 440*260*460mm/unit 520*440*470mm/2units
Weight:9kg
Applications:
Portable Multiparameter Patient Monitor apply to ICU, CCU, operation, adult, pediatrics and neonatal patient
Specifications:
Portable Multiparameter Patient Monitor:
Standard parameter: ECG, RESP, NIBP, SpO2, TEMP, PR.
12.1" large-screen color TFT display
7-lead ECG waveforms display ,big font observational interface
Reviewable ECG waveforms, Maximum 72 hours reviewing graphic trends
Digital SpO2 technique, precise measurement for weak perfusion and finger shaking
Arrhythmia and S-T segment analysis and pacemaker detection
Protection against interference from defibrillation and electrosurgical Unit
Adjustable 3 level audio and visual alarm
Applicable to ICU, CCU, operation, adult, pediatrics and neonatal patient
Built-in high-capacity battery, Battery-low indicator
Optional with thermal recorder, IBP and ETCO2
Competitive Advantage:
We provide the whole life time guarantee for inside boards of patient monitor, except man-made damage or burnt then can't be repaired.
Lead Mode 5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V)
Lead selection I, II, III, avR, avL, avF, V,
Waveform 2 ch
Lead mode 3 Leads ( R, L, F or RA, LA, LL)
Lead selection I, II, III,
Waveform 1 ch
Gain ´2.5mm/mV, ´5.0mm/mV, ´10mm/mV, ´20mm/mV, auto
HR and Alarm
Range
Adult 15 ~ 300 bpm
Neo/Ped 15 ~ 350 bpm
Accuracy ± 1% or ± 1bpm,which great
Resolution 1 bpm
Sensitivity > 200 (uV P-P)
Differential Input Impedance > 5 MΩ
CMRR
Monitor > 105 dB
Operation > 105 dB
Diagnosis > 85 dB
Electrode offset potential ±300mV
Leakage Current < 10 uA
Baseline Recovery < 3 S After Defi.
ECG Signal Range ±8 m V ( Vp-p )
Bandwidth
Surgery 1 ~ 15 Hz
Monitor 0.5 ~ 35 Hz
Diagnostic 0.05 ~ 100 Hz
Calibration Signal 1 (mV p-p), Accuracy :±5%
ST Segment Monitoring Range
Measure and Alarm -2.0 ~ +2.0 mV
ARR Detecting
Type ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC
Alarm Available
Review Available
Method Impedance between R-F(RA-LL)
Differential Input Impedance >2.5 MΩ
Measuring Impedance Range: 0.3~5.0Ω
Base line Impedance Range: 0 – 2.5 KΩ
Bandwidth 0.3 ~ 2.5 Hz
Resp. Rate
Measuring and Alarm Range
Adult 0 ~ 120 rpm
Neo/Ped 0 ~ 150 rpm
Resolution 1 rpm
Accuracy ±2 rpm
Apnea Alarm 10 ~ 40 S
Method Oscillometric
Mode Manual, Auto, STAT
Measuring Interval in AUTO Mode
1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min)
Measuring Period in STAT Mode 5 Min
Pulse Rate Range 40 ~ 240 bpm
Alarm Type SYS, DIA, MEAN
Measuring and alarm range
Adult Mode
SYS 40 ~ 270 mmHg
DIA 10 ~ 215 mmHg
MEAN 20 ~ 235 mmHg
Pediatric Mode
SYS 40 ~ 200 mmHg
DIA 10 ~ 150 mmHg
MEAN 20 ~ 165 mmHg
Neonatal Mode
SYS 40 ~ 135 mmHg
DIA 10 ~ 100 mmHg
MEAN 20 ~ 110 mmHg
Resolution
Pressure 1mmHg
Accuracy
Pressure
Maximum Mean error ±5mmHg
Maximum Standard deviation ±8mmHg
Overpressure Protection
Adult Mode 297±3 mmHg
Pediatric Mode 240±3 mmHg
Neonatal Mode 147±3 mmHg
Measuring Range 0 ~ 100 %
Alarm Range 0 ~ 100 %
Resolution 1 %
Accuracy
70% ~ 100% ±2 %
0% ~ 69% unspecified
Actualization interval about 1 Sec.
Alarm Delay 10 Sec.
Pulse Rate
Measuring and Alarm Range
0~254bpm
Resolution 1bpm
Accuracy ±2bpm
Channel 1
Measuring and Alarm Range 0 ~ 50 °C
Resolution 0.1°C
Accuracy ±0.1°C
Actualization interval about 1 Sec.
Average Time Constant < 10 Sec.
Dimension :350 mm (W) x 330mm ( D ) x 330mm ( H )
Weight:Gross 7KLG / Net 5KG
Standard Accessories:
Neonatal / Package Type SPO2 Probe:
Printer, ETCO2 optional:
Packing: